Colour | Illumination/ viewing system | Reflectance: di:8°, de:8° (diffused illumination, 8° viewing) Conforms to CIE No.15 (2004), ISO7724/1, ASTM E1164, DIN 5033 Teil7 and JIS Z 8722 Condition c standards. |
Transmittance: di:0°, de:0° (diffused illumination, 0-degree viewing) Conforms to CIE No.15 (2004), ASTM E-1164, DIN 5033 Teil 7 and JIS Z 8722 Condition g standards. |
| N/A |
Integrating sphere size | Ø152 mm |
Detector | Dual 40-element silicon photodiode array |
Spectral separation device | Planar diffraction grating |
Wavelength range | 360-740 nm |
Wavelength pitch | 10 nm |
Half bandwidth | approx. 10 nm |
Measurement range | 0-200% |
Resolution: 0.01% |
Light source | 3 Pulsed Xenon lamps (NUVC) | 1 Pulsed Xenon lamp (UV full only) |
Light source life time | more than 1 Million |
Illumination / Measurement area [mm] | LAV: Ø30.0 / Ø25.4 LMAV: Ø20.0 /Ø16.0 MAV: Ø11.0 / Ø8.0 SAV: Ø7.0 / Ø4.0 Trans: Ø24.0 / Ø17.0 | LAV: Ø30.0 / Ø25.4 MAV: Ø11.0 / Ø8.0 SAV: Ø7.0 / Ø 4.0 |
Measurement time | Approx. 3.5sec (SCI + SCE measurement) Approx. 4sec (SCI + SCE + gloss measurement) | Approx. 3.5sec (SCI + SCE measurement) |
Min. measurement interval | Approx. 4sec (SCI + SCE measurement), Approx. 4.5sec (SCI or SCE + gloss measurement) | Approx. 4sec (SCI + SCE measurement) |
Repeatability | Colorimetric values: Std. dev. within ΔE*ab 0.02 Spectral reflectance: Std. dev. within 0.1% (When a white calibration plate measured 30 times at 10sec intervals after white calibration) | Std. dev. within ΔE*ab 0.03 |
IIA | Within ΔE*ab 0.12 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body. | Within ΔE*ab 0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body. |
UV control | NUVC*1 (UV100 (Full UV), UV adjusted, UV0. With 400nm and 420nm UV cutoff filters) | No adjustment function (UV100%) |
Gloss | Measurement geometry | 60° (complies to ISO 2813, ISO 7668 (MAV), ASTM D523-08, ASTM D2457-13, DIN 67530, JIS-Z8741 (MAV), JIS-K5600) | N/A |
Light source | White LED |
Detector | Silicon photo diode |
Measurement range | 0-200 GU |
Resolution: 0.01 GU |
Measurement area [mm] | MAV (LAV/LMAV/MAV color measurement area): Ø10.0 x 8.0 |
SAV (SAV color measurement area): Ø3.0 |
Repeatability (MAV) | 0-10 GU: within 0.1 GU |
10-100 GU: within 0.2 GU |
>100 GU: within 0.2% of indicated value (Standard deviation) |
IIA (MAV) | 0-10 GU: ±0.2 GU |
10-100 GU: ±0.5 GU |
Sample preview | RGB Camera |
Internal Performance Check*2 | WAA (Wavelength Analysis & Adjustment) Technology |
Interfacing | USB 2.0 |
Operation temperature / humidity range | 13-33°C / rH 80% or less (at 35°C) with no condensation |
Storage temperature / humidity range | 0-40°C / rH 80% or less (at 35°C) with no condensation |
Size (W×H×D) | Approx. 248×250×498 mm | Approx. 300×677×315 mm | Approx. 248×250×498 mm |