| Illumination/viewing system | Reflectance | di:8°, de:8° (diffuse illumination/8° viewing angle) |
| SCI (specular component included)/SCE (specular component excluded) switchable & simultaneously |
| Conforms to CIE No.15(2004), ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7 and JIS Z 8722 condition c standard. |
| Transmittance | di:0°, de:0° (diffuse illumination/0° viewing angle) |
| Conforms to CIE No.15(2004), ASTM E 1164, DIN 5033 Teil 7 and JIS Z 8722 condition g standard. |
| Integrating sphere size | Ø152 mm/6 inches |
| Detector | 38-element silicon photodiode array |
| Spectral separation device | Diffraction grating |
| Wavelength range | 360 to 740 nm |
| Wavelength pitch | 10 nm |
| Half bandwidth | Approx. 14 nm average |
| Measuring range | 0 to 200%; Resolution: 0.001% |
| Light source | Pulsed xenon arc lamp |
| Measurement/illumination area | Reflectance | Changeable between SAV, MAV, LMAV and LAV |
| SAV : 3x5 mm measurement / 5x7 mm illumination |
| MAV : ø8 mm measurement/ ø11 mm illumination |
| LMAV : ø16 mm measurement / ø20 mm illumination |
| LAV : ø25.4 mm measurement / ø28 mm illumination |
| Transmittance | Approx. Ø20 mm / ø25 mm |
| Repeatability | White | Colorimetric values : Standard deviation within ΔE ab 0.005 |
| Spectral reflectance : Standard deviation within 0.05% |
| (When a white calibration plate is measured 30 times at 10-second intervals after white calibration) |
| Black | Colorimetric values : Standard deviation within AE ab 0.02 |
| Spectral reflectance : Standard deviation within 0.02% |
| (When a black tile (BCRA Serles II; reflectance: 1%) is measured 30 times at 10-second intervals after white calibration) |
| Inter-instrument agreement | Within ΔE*ab 0.08 |
| (Based on average for 12 BCRA Series II colour tiles; LAV/SCI. Compared to values measured with a master body under Konica Minolta standard measurement conditions) |
| UV adjustment | UV setting : UV cutoff filter : 400 nm |
| Computer controlled: continuously variable, 0.0%~100.0% (1000step) |
| Sample temperature measurement | Accuracy (Within operating temperature/humidity range) |
| SAV : ±1.2°C |
| LMAV, MAV : ±0.8°C |
| LAV : ±0.5°C |
| Measurement time | SCI or SCE : Approx. 2 s |
| SCI or SCE with measuring sample temperature : Approx. 4.5 s |
| SCI+SCE : Approx. 5 s |
| SCI+SCE with measuring sample temperature : Approx. 5 s |
| Transmittance : Approx. 2 s |
| Minimum interval between measurements | SCI or SCE : Approx. 3 s |
| SCI or SCE with measuring sample temperature : Approx. 5 s |
| SCI+SCE : Approx. 6 s |
| SCI+SCE with measuring sample temperature : Approx. 6 s |
| Transmittance : Approx. 3 s |
| Transmittance chamber | Maximum sample thickness : Approx. 50 mm |
| Maximum sample length : |
| Unlimited (no sides when transmittance chamber cover is open) |
| Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed |
| Camera viewfinder function | Using internal camera. |
| * Image viewable/copiable using optional software such as SpectraMagic NX2 |
| Internal Performance Check*1 | WAA (Wavelength Analysis & Adjustment) Technology |
| Ambient temperature sensor | Yes |
| Interface | USB2.0 |
| Power | Dedicated AC adapter |
| Size (HxWxD) | Approx. 307(H) x 271(W) x 600(D)mm |
| Weight | Approx. 20.0kg |
| Operating temperature/humidity range | Temperature: 13 to 33°C, |
| Relative humidity: 80% or less (at 33°C) with no condensation |
| Storage temperature/humidity range | Temperature: 0 to 40°C, |
| Relative humidity: 80% or less (at 35°C) with no condensation |
| Standard Accessories | White Calibration Plate; Target Masks (SAV,MAV,LMAV,LAV); |
| Zero Calibration Box; USB Cable (3 m); AC Adapter |
| Optional Accessories | Colour Data Software SpectraMagic™ NX2; Transmittance Specimen Holder; Cells (Glass; 2 mm, 10 mm, 20 mm); Plastic Cells (2 mm, 10 mm, 20 mm); Transmittance Zero Calibration Plate; Colour Plates; Green tile; Dust Cover |